Fiji updates EN ISO 11611 to version: 2015

September 2019, AITEX lab (Spain) has tested Fiji fr fabric to the new version of safety standard for Protective clothing for use in welding and allied processes. Fiji confirmed its compliance to ISO EN 11611:2015 and received a new certificate, which you can see below.

According to EN ISO 11611:2015, Fiji has been successfully tested to the following tests:

  1. Limited Flame Spread (ISO 15025:2002, Method A) – performance level  A1

    Fiji results for new samples and after 5 washes @60ºC ISO 6330:2012, method 6N, F drying (tumble dry)

  • Flaming to top or either side edge: No – PASS
  • Hole formation: No – PASS
  • Loose waste: No – PASS
  • After flame time (s): No – PASS
  • Afterglow time (s): No – PASS

 

  1. Limited Flame Spread (ISO 15025:2002, Method A) – performance level  A2

    Fiji results for new samples and after 5 washes @60ºC ISO 6330:2012, method 6N, F drying (tumble dry)

  • Flaming to top or either side edge: No – PASS
  • Hole formation: No – PASS
  • Loose waste: No – PASS
  • After flame time (s): No – PASS
  • Afterglow time (s): No – PASS

 

  1. Determination of dimensional change in domestic washing and drying (ISO 5077:2008) – performance level  PASS

    Fiji results for new samples and after 5 washes @60ºC ISO 6330:2012, method 6N, F drying (tumble dry)

DirectionDimensional
change (%)
Warp-1,0
Weft+1,0

 

  1. Fabric Tensile Strength and Elongation (EN ISO 13934-1:2013) – performance level  PASS
  • Wrap: 1200N PASS (must resist ≥ 400 N)
  • Weft: 620N PASS (must resist ≥ 400 N)

 

  1. Determination of Tear Resistance (EN ISO 13937-2:2000) – performance level – PASS
  • Warp: 21NPASS (must be ≥ 15N)
  • Weft: 24NPASS (must be ≥ 15N)

 

  1. Small Molten Metal Splash (ISO 9150:1988) – performance level  Class 1
  • Average value Molten iron (g): > 18
Class 1Minimum 15 drops 
Class 2Minimum 25 drops 

 

  1. Radiant Heat (ISO 6942)  performance level C1
  • Average value for RHTI 24 (s): 14,1

Heat transfer index RHTI 24

Class 1

Class 1

RHTI 24≥ 7s≥ 16s

 

  1. Vertical Resistance (EN 1149-2:1997)  – performance level Pass
  • Average value: 7,99∙107

According to the Standard UNE-EN ISO 11611:2015, the vertical electric resistance must be greater than 10Ohm

 

ISO 11611:2015 specifies minimum basic safety requirements and test methods for protective clothing during welding and allied processes with comparable risks. This type of protective clothing is intended to protect the wearer against spatter (small splashes of molten metal), short contact time with flame, radiant heat from an electric arc used for welding and allied processes.

Fiji is a light flame retardant fabric with classic twill weave, developed specially for light flame retardant clothing. Fiji protective fabric is recommended for use as a middle layer of FR-clothing, like shirts, vests, light pants, or even light overalls for hot climate. 

You can find all the certificates and additional information on the product page.

 

[foogallery id=”6195″]
Scroll to Top