Etna flame retardant fabric is updated to EN 11612:2015

August 2019, our modacrylic flame retardant fabric Etna has been successfully tested to EN 11612:2015.
According to EN ISO 11612:2015, Etna has been successfully tested to the following tests:

  1. Heat Resistance (ISO 17493:2016) – performance level – PASS

    Etna results for samples and after 5 washing cycles at 60ºC, according to the standard ISO 6330:2012, method 6N, F drying (tumble dry)

Test

Flame

Melting

Shrinking

Result

No

No

Warp -0,3%
Weft -0,4%

RequirementNo layer can igniteNo layer
can melt 
No layer shrinks more than 5%

 

  1. Limited Flame Spread (ISO 15025:2016, Method A) – performance level  A1

    Etna results for new samples and after 5 washes @60ºC ISO 6330:2012, method 6N, F drying (tumble dry)

  • Flaming to top or either side edge: No – PASS
  • Hole formation: No – PASS
  • Loose waste: No – PASS
  • After flame time (s): No – PASS
  • Afterglow time (s): No – PASS

 

  1. Limited Flame Spread (ISO 15025:2016, Method B) – performance level  A2

    Etna results for new samples and after 5 washes @60ºC ISO 6330:2012, method 6N, F drying (tumble dry)

  • Flaming to top or either side edge: No – PASS
  • Hole formation: No – PASS
  • Loose waste: No – PASS
  • After flame time (s): No – PASS
  • Afterglow time (s): No – PASS

 

  1. Fabric tensile strength and rupture elongation (ISO 13934-1:2013)
    The relative expanded uncertainty of Tear resistance is ±3.9% assay value of the measured, for a probability of coverage of 95%. Is determined the Lengthwise and Crosswise directions, respectively.

REQUISITE ACCORDING TO EN ISO 11612:2015

The external material must resist a determination of tear resistance in both directions ≥ 10 N.

  • Warp: – 1300N- PASS
  • Weft: 790N – PASS

Elongation 

  • Warp: 19%- PASS
  • Weft: 21,1% – PASS

 

  1. Determining Heat Transmission on Exposure to Flame (ISO 9151:2016)  performance level B1
  • Average value for HTIa24 (s): 6,0 

Performance 
level

Range of HTIa24 
values (s)

 

Minimum Maximum

B1

4,0 < 10,0

B2

10,0 < 20,0

B3

20,0

a: Heat transfer index, as defined in ISO 9151.

 

  1. Radiant Heat (ISO 6942)  performance level C1
  • Average value for RHTI 24 (s): 14,8

Performance 
level

Range of HTIa24 
values (s)

 

Minimum Maximum

C1

7,0 < 20,0

C2

 20,0 < 50,0

C3

 50,0 < 95,0

C4

 95,0

ª: Heat transfer index, as defined in ISO 6942

 

  1. Contact Heat (ISO 12127-1:2015)  – performance level F1
  • Average threshold time (S): 8,1

ISO 12127-1:2007 specifies a test method for the determination of contact heat transmission. It is applicable to protective clothing (including hand protectors) and its constituent materials intended to protect against high contact temperatures. ISO 12127-1:2007 is restricted to contact temperatures between 100°C and 500°C.

Performance 
level

Threshold time (s)

Minimum

Maximum

F1

5,0

< 10,0

F2

10,0

< 15,0

F3

15,0

The performance requirements set out in ISO 11612:2015 are applicable to garments which could be worn for a wide range of end uses, where there is a need for clothing with limited flame spread properties and where the user can be exposed to radiant or convective or contact heat or to molten metal splashes.

 

  1. Assessment of Resistance of materials to Molten metal splash (EN ISO 9185:2008) – performance level  E3
  • Average value Molten iron (g): > 203
Performance levelMolten iron (g)
 Min.Max.
E160< 120
E2120< 200
E3200 

 

Etna flame retardant fabric is made of 350 gsm cotton with antistatic yarn and designed for use in Metallurgy and other industries. This fabric is best used for protective jackets, pants, overalls and other FR clothing.

You can find all the certificates and additional information on the Etna product page.

 

[foogallery id=”6631″]